NIST · Shared reference library

NIST SP 800-53 Rev. 5 Common Control Library

Browse 1,193 controls and enhancements across 20 security and privacy families. Use the GovRAMP crosswalk to locate controls referenced by Security Snapshot, Core, and Moderate.

A shared catalog supports common-control planning; designation as a common, hybrid, or system-specific control depends on your organization’s implementation and inheritance decisions.

Sources and crosswalk scope

NIST OSCAL content 5.1.1+u4, retrieved 2026-09-18. GovRAMP Snapshot v1.4 and Core selection from Moderate v1.06 reference the December 2020 Rev. 5 text. Mappings establish exact identifier correspondence, not identical requirements, inherited implementation, or GovRAMP authorization. GovRAMP parameters and additional requirements remain authoritative for each program. Full Moderate, High, and other programs are not mapped here. Withdrawn controls are retained for reference.

Official pinned NIST source

SHA-256: 81cf2de45ede9aef3de7ce09d65ea9d32f662c483bbf916f6e346292b22f7763

Reset

12 matching controls · Page 1 of 1

Assessment, Authorization, and Monitoring · Base control

CA-7 · Continuous Monitoring

Control statement and discussion

NIST control statement

Develop a system-level continuous monitoring strategy and implement continuous monitoring in accordance with the organization-level continuous monitoring strategy that includes: a. Establishing the following system-level metrics to be monitored: [Assignment: system-level metrics]; b. Establishing [Assignment: frequencies] for monitoring and [Assignment: frequencies] for assessment of control effectiveness; c. Ongoing control assessments in accordance with the continuous monitoring strategy; d. Ongoing monitoring of system and organization-defined metrics in accordance with the continuous monitoring strategy; e. Correlation and analysis of information generated by control assessments and monitoring; f. Response actions to address results of the analysis of control assessment and monitoring information; and g. Reporting the security and privacy status of the system to [Assignment: organization-defined personnel or roles] [Assignment: organization-defined frequency].

Discussion

Continuous monitoring at the system level facilitates ongoing awareness of the system security and privacy posture to support organizational risk management decisions. The terms "continuous" and "ongoing" imply that organizations assess and monitor their controls and risks at a frequency sufficient to support risk-based decisions. Different types of controls may require different monitoring frequencies. The results of continuous monitoring generate risk response actions by organizations. When monitoring the effectiveness of multiple controls that have been grouped into capabilities, a root-cause analysis may be needed to determine the specific control that has failed. Continuous monitoring programs allow organizations to maintain the authorizations of systems and common controls in highly dynamic environments of operation with changing mission and business needs, threats, vulnerabilities, and technologies. Having access to security and privacy information on a continuing basis through reports and dashboards gives organizational officials the ability to make effective and timely risk management decisions, including ongoing authorization decisions. Automation supports more frequent updates to hardware, software, and firmware inventories, authorization packages, and other system information. Effectiveness is further enhanced when continuous monitoring outputs are formatted to provide information that is specific, measurable, actionable, relevant, and timely. Continuous monitoring activities are scaled in accordance with the security categories of systems. Monitoring requirements, including the need for specific monitoring, may be referenced in other controls and control enhancements, such as [AC-2g](#ac-2_smt.g), [AC-2(7)](#ac-2.7), [AC-2(12)(a)](#ac-2.12_smt.a), [AC-2(7)(b)](#ac-2.7_smt.b), [AC-2(7)(c)](#ac-2.7_smt.c), [AC-17(1)](#ac-17.1), [AT-4a](#at-4_smt.a), [AU-13](#au-13), [AU-13(1)](#au-13.1), [AU-13(2)](#au-13.2), [CM-3f](#cm-3_smt.f), [CM-6d](#cm-6_smt.d), [CM-11c](#cm-11_smt.c), [IR-5](#ir-5), [MA-2b](#ma-2_smt.b), [MA-3a](#ma-3_smt.a), [MA-4a](#ma-4_smt.a), [PE-3d](#pe-3_smt.d), [PE-6](#pe-6), [PE-14b](#pe-14_smt.b), [PE-16](#pe-16), [PE-20](#pe-20), [PM-6](#pm-6), [PM-23](#pm-23), [PM-31](#pm-31), [PS-7e](#ps-7_smt.e), [SA-9c](#sa-9_smt.c), [SR-4](#sr-4), [SC-5(3)(b)](#sc-5.3_smt.b), [SC-7a](#sc-7_smt.a), [SC-7(24)(b)](#sc-7.24_smt.b), [SC-18b](#sc-18_smt.b), [SC-43b](#sc-43_smt.b) , and [SI-4](#si-4).

GovRAMP crosswalk

Maintenance · Base control

MA-5 · Maintenance Personnel

Control statement and discussion

NIST control statement

a. Establish a process for maintenance personnel authorization and maintain a list of authorized maintenance organizations or personnel; b. Verify that non-escorted personnel performing maintenance on the system possess the required access authorizations; and c. Designate organizational personnel with required access authorizations and technical competence to supervise the maintenance activities of personnel who do not possess the required access authorizations.

Discussion

Maintenance personnel refers to individuals who perform hardware or software maintenance on organizational systems, while [PE-2](#pe-2) addresses physical access for individuals whose maintenance duties place them within the physical protection perimeter of the systems. Technical competence of supervising individuals relates to the maintenance performed on the systems, while having required access authorizations refers to maintenance on and near the systems. Individuals not previously identified as authorized maintenance personnel—such as information technology manufacturers, vendors, systems integrators, and consultants—may require privileged access to organizational systems, such as when they are required to conduct maintenance activities with little or no notice. Based on organizational assessments of risk, organizations may issue temporary credentials to these individuals. Temporary credentials may be for one-time use or for very limited time periods.

GovRAMP crosswalk

Physical and Environmental Protection · Base control

PE-2 · Physical Access Authorizations

Control statement and discussion

NIST control statement

a. Develop, approve, and maintain a list of individuals with authorized access to the facility where the system resides; b. Issue authorization credentials for facility access; c. Review the access list detailing authorized facility access by individuals [Assignment: frequency] ; and d. Remove individuals from the facility access list when access is no longer required.

Discussion

Physical access authorizations apply to employees and visitors. Individuals with permanent physical access authorization credentials are not considered visitors. Authorization credentials include ID badges, identification cards, and smart cards. Organizations determine the strength of authorization credentials needed consistent with applicable laws, executive orders, directives, regulations, policies, standards, and guidelines. Physical access authorizations may not be necessary to access certain areas within facilities that are designated as publicly accessible.

GovRAMP crosswalk

Physical and Environmental Protection · Enhancement

PE-2(1) · Access by Position or Role

View parent control
Control statement and discussion

NIST control statement

Authorize physical access to the facility where the system resides based on position or role.

Discussion

Role-based facility access includes access by authorized permanent and regular/routine maintenance personnel, duty officers, and emergency medical staff.

GovRAMP crosswalk

Not selected in the imported Snapshot or Core sets. This does not establish exclusion from other GovRAMP baselines.

Physical and Environmental Protection · Enhancement

PE-2(2) · Two Forms of Identification

View parent control
Control statement and discussion

NIST control statement

Require two forms of identification from the following forms of identification for visitor access to the facility where the system resides: [Assignment: list of acceptable forms of identification].

Discussion

Acceptable forms of identification include passports, REAL ID-compliant drivers’ licenses, and Personal Identity Verification (PIV) cards. For gaining access to facilities using automated mechanisms, organizations may use PIV cards, key cards, PINs, and biometrics.

GovRAMP crosswalk

Not selected in the imported Snapshot or Core sets. This does not establish exclusion from other GovRAMP baselines.

Physical and Environmental Protection · Enhancement

PE-2(3) · Restrict Unescorted Access

View parent control
Control statement and discussion

NIST control statement

Restrict unescorted access to the facility where the system resides to personnel with [Selection (one-or-more): security clearances for all information contained within the system; formal access authorizations for all information contained within the system; need for access to all information contained within the system; [Assignment: physical access authorizations] ].

Discussion

Individuals without required security clearances, access approvals, or need to know are escorted by individuals with appropriate physical access authorizations to ensure that information is not exposed or otherwise compromised.

GovRAMP crosswalk

Not selected in the imported Snapshot or Core sets. This does not establish exclusion from other GovRAMP baselines.

Physical and Environmental Protection · Base control

PE-20 · Asset Monitoring and Tracking

Control statement and discussion

NIST control statement

Employ [Assignment: asset location technologies] to track and monitor the location and movement of [Assignment: assets] within [Assignment: controlled areas].

Discussion

Asset location technologies can help ensure that critical assets—including vehicles, equipment, and system components—remain in authorized locations. Organizations consult with the Office of the General Counsel and senior agency official for privacy regarding the deployment and use of asset location technologies to address potential privacy concerns.

GovRAMP crosswalk

Not selected in the imported Snapshot or Core sets. This does not establish exclusion from other GovRAMP baselines.

Physical and Environmental Protection · Base control

PE-21 · Electromagnetic Pulse Protection

Control statement and discussion

NIST control statement

Employ [Assignment: protective measures] against electromagnetic pulse damage for [Assignment: system and system components].

Discussion

An electromagnetic pulse (EMP) is a short burst of electromagnetic energy that is spread over a range of frequencies. Such energy bursts may be natural or man-made. EMP interference may be disruptive or damaging to electronic equipment. Protective measures used to mitigate EMP risk include shielding, surge suppressors, ferro-resonant transformers, and earth grounding. EMP protection may be especially significant for systems and applications that are part of the U.S. critical infrastructure.

GovRAMP crosswalk

Not selected in the imported Snapshot or Core sets. This does not establish exclusion from other GovRAMP baselines.

Physical and Environmental Protection · Base control

PE-22 · Component Marking

Control statement and discussion

NIST control statement

Mark [Assignment: system hardware components] indicating the impact level or classification level of the information permitted to be processed, stored, or transmitted by the hardware component.

Discussion

Hardware components that may require marking include input and output devices. Input devices include desktop and notebook computers, keyboards, tablets, and smart phones. Output devices include printers, monitors/video displays, facsimile machines, scanners, copiers, and audio devices. Permissions controlling output to the output devices are addressed in [AC-3](#ac-3) or [AC-4](#ac-4) . Components are marked to indicate the impact level or classification level of the system to which the devices are connected, or the impact level or classification level of the information permitted to be output. Security marking refers to the use of human-readable security attributes. Security labeling refers to the use of security attributes for internal system data structures. Security marking is generally not required for hardware components that process, store, or transmit information determined by organizations to be in the public domain or to be publicly releasable. However, organizations may require markings for hardware components that process, store, or transmit public information in order to indicate that such information is publicly releasable. Marking of system hardware components reflects applicable laws, executive orders, directives, policies, regulations, and standards.

GovRAMP crosswalk

Not selected in the imported Snapshot or Core sets. This does not establish exclusion from other GovRAMP baselines.

Physical and Environmental Protection · Base control

PE-23 · Facility Location

Control statement and discussion

NIST control statement

a. Plan the location or site of the facility where the system resides considering physical and environmental hazards; and b. For existing facilities, consider the physical and environmental hazards in the organizational risk management strategy.

Discussion

Physical and environmental hazards include floods, fires, tornadoes, earthquakes, hurricanes, terrorism, vandalism, an electromagnetic pulse, electrical interference, and other forms of incoming electromagnetic radiation. The location of system components within the facility is addressed in [PE-18](#pe-18).

GovRAMP crosswalk

Not selected in the imported Snapshot or Core sets. This does not establish exclusion from other GovRAMP baselines.

Program Management · Base control

PM-31 · Continuous Monitoring Strategy

Control statement and discussion

NIST control statement

Develop an organization-wide continuous monitoring strategy and implement continuous monitoring programs that include: a. Establishing the following organization-wide metrics to be monitored: [Assignment: metrics]; b. Establishing [Assignment: monitoring frequencies] and [Assignment: assessment frequencies] for control effectiveness; c. Ongoing monitoring of organizationally-defined metrics in accordance with the continuous monitoring strategy; d. Correlation and analysis of information generated by control assessments and monitoring; e. Response actions to address results of the analysis of control assessment and monitoring information; and f. Reporting the security and privacy status of organizational systems to [Assignment: organization-defined personnel or roles] [Assignment: organization-defined frequency].

Discussion

Continuous monitoring at the organization level facilitates ongoing awareness of the security and privacy posture across the organization to support organizational risk management decisions. The terms "continuous" and "ongoing" imply that organizations assess and monitor their controls and risks at a frequency sufficient to support risk-based decisions. Different types of controls may require different monitoring frequencies. The results of continuous monitoring guide and inform risk response actions by organizations. Continuous monitoring programs allow organizations to maintain the authorizations of systems and common controls in highly dynamic environments of operation with changing mission and business needs, threats, vulnerabilities, and technologies. Having access to security- and privacy-related information on a continuing basis through reports and dashboards gives organizational officials the capability to make effective, timely, and informed risk management decisions, including ongoing authorization decisions. To further facilitate security and privacy risk management, organizations consider aligning organization-defined monitoring metrics with organizational risk tolerance as defined in the risk management strategy. Monitoring requirements, including the need for monitoring, may be referenced in other controls and control enhancements such as, [AC-2g](#ac-2_smt.g), [AC-2(7)](#ac-2.7), [AC-2(12)(a)](#ac-2.12_smt.a), [AC-2(7)(b)](#ac-2.7_smt.b), [AC-2(7)(c)](#ac-2.7_smt.c), [AC-17(1)](#ac-17.1), [AT-4a](#at-4_smt.a), [AU-13](#au-13), [AU-13(1)](#au-13.1), [AU-13(2)](#au-13.2), [CA-7](#ca-7), [CM-3f](#cm-3_smt.f), [CM-6d](#cm-6_smt.d), [CM-11c](#cm-11_smt.c), [IR-5](#ir-5), [MA-2b](#ma-2_smt.b), [MA-3a](#ma-3_smt.a), [MA-4a](#ma-4_smt.a), [PE-3d](#pe-3_smt.d), [PE-6](#pe-6), [PE-14b](#pe-14_smt.b), [PE-16](#pe-16), [PE-20](#pe-20), [PM-6](#pm-6), [PM-23](#pm-23), [PS-7e](#ps-7_smt.e), [SA-9c](#sa-9_smt.c), [SC-5(3)(b)](#sc-5.3_smt.b), [SC-7a](#sc-7_smt.a), [SC-7(24)(b)](#sc-7.24_smt.b), [SC-18b](#sc-18_smt.b), [SC-43b](#sc-43_smt.b), [SI-4](#si-4).

GovRAMP crosswalk

Not selected in the imported Snapshot or Core sets. This does not establish exclusion from other GovRAMP baselines.

System and Information Integrity · Base control

SI-12 · Information Management and Retention

Control statement and discussion

NIST control statement

Manage and retain information within the system and information output from the system in accordance with applicable laws, executive orders, directives, regulations, policies, standards, guidelines and operational requirements.

Discussion

Information management and retention requirements cover the full life cycle of information, in some cases extending beyond system disposal. Information to be retained may also include policies, procedures, plans, reports, data output from control implementation, and other types of administrative information. The National Archives and Records Administration (NARA) provides federal policy and guidance on records retention and schedules. If organizations have a records management office, consider coordinating with records management personnel. Records produced from the output of implemented controls that may require management and retention include, but are not limited to: All XX-1, [AC-6(9)](#ac-6.9), [AT-4](#at-4), [AU-12](#au-12), [CA-2](#ca-2), [CA-3](#ca-3), [CA-5](#ca-5), [CA-6](#ca-6), [CA-7](#ca-7), [CA-8](#ca-8), [CA-9](#ca-9), [CM-2](#cm-2), [CM-3](#cm-3), [CM-4](#cm-4), [CM-6](#cm-6), [CM-8](#cm-8), [CM-9](#cm-9), [CM-12](#cm-12), [CM-13](#cm-13), [CP-2](#cp-2), [IR-6](#ir-6), [IR-8](#ir-8), [MA-2](#ma-2), [MA-4](#ma-4), [PE-2](#pe-2), [PE-8](#pe-8), [PE-16](#pe-16), [PE-17](#pe-17), [PL-2](#pl-2), [PL-4](#pl-4), [PL-7](#pl-7), [PL-8](#pl-8), [PM-5](#pm-5), [PM-8](#pm-8), [PM-9](#pm-9), [PM-18](#pm-18), [PM-21](#pm-21), [PM-27](#pm-27), [PM-28](#pm-28), [PM-30](#pm-30), [PM-31](#pm-31), [PS-2](#ps-2), [PS-6](#ps-6), [PS-7](#ps-7), [PT-2](#pt-2), [PT-3](#pt-3), [PT-7](#pt-7), [RA-2](#ra-2), [RA-3](#ra-3), [RA-5](#ra-5), [RA-8](#ra-8), [SA-4](#sa-4), [SA-5](#sa-5), [SA-8](#sa-8), [SA-10](#sa-10), [SI-4](#si-4), [SR-2](#sr-2), [SR-4](#sr-4), [SR-8](#sr-8).

GovRAMP crosswalk